

- #Varian star chromatography workstation manual manuals#
- #Varian star chromatography workstation manual Pc#

#Varian star chromatography workstation manual manuals#
The purchaser, by bidding on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer.Varian CP-3800 Triple FID Chrompack Gas Chromatograph with Varian Agilent CP-8410 AutoSampler, Software and Manuals The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment. Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. This is a genuine product from this manufacturer. This is our way of saying thank you for allowing us to serve you.

We pledge to offer the best service and warranty to all of our customers! We are extending a 30 Day warranty on this item. Varian 3900 Gas Chromatograph (no detector installed)ģ0 Day warranty.Removed from laboratory upgrading equipment. The Varian CP-8410 AutoInjector accommodates 2, 5, and 10 mL sample vials.ĭetector flows: air, 0 to 500 mL/min hydrogen, 0 to 50 mL/min make-up 0 to 50 mL/min The Varian CP-8400 AutoSampler delivers high-throughput automation for up to 100 samples. Maximum stored methods with battery protection: 5 VFD display: 2 lines, 20 characters per line
#Varian star chromatography workstation manual Pc#
Two channels: makeup gas and reference gas, non-hydrogenįlow rate: 0 to 50 mL/min, 1 mL/min incrementsĪnalog output: 0 to 1V or 0 to 10V, standardĭigital output and PC workstation control: TCP/IP with industry standard Ethernet 10Base-T (optional) Total flow: 0 to 1500 mL/min depends on set pressure, 1 mL/min increments Pressure range: 0 to 100 psi, 0.1 psi increments Split range: 1 to 10,000 (column dependent) Maximum temperature ramp rate: 100 ☌/minĬool-down rate: 450 ☌ to 50 ☌ in 5.2 min Temperature-programmed ramps: 7 ramps with 8 isothermal holds Temperature range: ambient +10 ☌ to 450 ☌ with liquid CO2 option, It is fully functional as a standalone GC or controlled through the Varian Star Workstation or the Galaxie Chromatography Data System Roll-back cover provides complete and easy access to both the injector and detector for routine maintenance.Ĭhoice of the CP-1177 isothermal split/splitless injector or the 1041 on-column megabore/packed injector.Ĭhoice of a gas sampling valve or a liquid sampling valve upstream of the liquid injector.Ĭhoice of the complete line of Varian autosamplers. Intuitive, icon-based keypad simplified operationĬompact and efficient Column Oven uses standard 7 in./17.5 cm diameter capillary columns, heats fast and cools down from 450☌ to 50☌ in only 5.2 minutes!įull EFC control of injectors and detectors. Small footprint (12.5inch/32 cm) saves precious bench space It is a single channel, fixed configuration GC incorporating the same outstanding electronic flow control (EFC), injector, detector and autosampler as the full-featured Varian CP-3800 GC. The 3900 GC is an easy-to-use, high-throughput GC designed to meet the requirements of the routine analytical laboratory.

Electronic flow control of detector and injector eliminates knobs to turn off, thus saving you time, increasing long term precision of the GC. Simple to use syringe trigger mechanism starts the GC upon injection. The Varian 3900 occupies less than half the workspace of many gas chromatograph (GC) units.
